manifest-import revision 293e3ab30a546cd932ee22f9d54b3979fcb52095
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# CDDL HEADER START
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# The contents of this file are subject to the terms of the
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# Common Development and Distribution License (the "License").
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# You may not use this file except in compliance with the License.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# See the License for the specific language governing permissions
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# and limitations under the License.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# When distributing Covered Code, include this CDDL HEADER in each
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# If applicable, add the following below this CDDL HEADER, with the
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# fields enclosed by brackets "[]" replaced with your own identifying
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# information: Portions Copyright [yyyy] [name of copyright owner]
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# CDDL HEADER END
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# Copyright (c) 2004, 2010, Oracle and/or its affiliates. All rights reserved.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# 0a Initialization.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsyncEMI_SERVICE="svc:/system/early-manifest-import:default"
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync echo "Usage: /lib/svc/method/manifest-import [-n]" \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync echo "-f and -d specify alternate repository and" \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync n) X=echo;;
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# Both -f and -d options must be specified together or not specified at all
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync[ -n "$ALT_REPOSITORY" -a -z "$ALT_MFST_DIR" ] && usage
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync[ -n "$ALT_MFST_DIR" -a -z "$ALT_REPOSITORY" ] && usage
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ $? -ne 0 ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync echo "WARNING: svccfg apply $1 failed" | tee /dev/msglog
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# If the smf/manifest table has file entries that are missing
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# then there is work to be done by the cleanup process.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync nw=`/lib/svc/bin/mfstscan $smfmfiles 2>&1 1>/dev/null`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# Upon upgrading to early manifest import code, preserve hashes of system
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# profiles which lived under /var/svc/profile so that svccfg apply would
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# not re-apply the profiles and overwrite user customizations. Simply
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# migrate manifestfile and hash values to new property groups named after
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# profiles under /etc/svc/profile. If the profiles don't really exist,
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# svccfg cleanup will remove the property groups in a later step.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# Existing generic.xml, inetd_services.xml, and name_service.xml symlinks
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# need to be preserved.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# Don't process site.xml profile since it is still supported under
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# /var/svc/profile directory.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # If /var is a separate fs, return and let Late Import
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Preserve hashes for the following profiles: generic (two
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # cases) and platform (uname -i, uname -m outputs).
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync gh=`/usr/bin/svcprop -p ${gn}/md5sum smf/manifest 2>/dev/null`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync glh=`/usr/bin/svcprop -p ${gln}/md5sum smf/manifest 2>/dev/null`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync plh=`/usr/bin/svcprop -p ${pln}/md5sum smf/manifest 2>/dev/null`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ $plm != $pl ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync plmh=`/usr/bin/svcprop -p ${plmn}/md5sum smf/manifest \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest addpg ${gn} framework
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest setprop ${gn}/md5sum = \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest setprop ${gn}/manifestfile = \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest addpg ${gln} framework
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest setprop ${gln}/md5sum = \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest setprop ${gln}/manifestfile = \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest addpg $pln framework
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest setprop $pln/md5sum = \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest setprop ${pln}/manifestfile = \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest addpg $plmn framework
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg -s smf/manifest setprop $plmn/md5sum = \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Move symlinks from /var/svc/profile to /etc/svc/profile
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync [ -L "$generic_prof" ] && mv $generic_prof /etc/svc/profile/
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync [ -L "$inetd_prof" ] && mv $inetd_prof /etc/svc/profile/
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync [ -L "$platform_prof" ] && mv $platform_prof /etc/svc/profile/
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# 2. Manifest import. Application directories first, then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# site-specific manifests.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync typeset logf="/etc/svc/volatile/manifest_import.$$"
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync nonsite_dirs=`/usr/bin/find $basedir/* -name site \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync -prune -o -type d -print -prune`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync nonsite_manifests=`/lib/svc/bin/mfstscan $nonsite_dirs`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync site_manifests=`/lib/svc/bin/mfstscan $basedir/site`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Upon boot, attempt to move the repository to tmpfs.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ -z "$ALT_REPOSITORY" -a -z "$ALT_MFST_DIR" ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Import the manifests while giving a running display of imports on
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync [ -d "$basedir/site" ] && dirs="$dirs $basedir/site"
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync $X /usr/sbin/svccfg import -p /dev/msglog $dirs > $logf 2>&1
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync grep "Loaded .*. smf(5) service descriptions" $logf > /dev/null 2>&1
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ $? -eq 0 ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ -s $logf ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync grep "smf(5) service descriptions failed to load" $logf > /dev/null 2>&1
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ $failures -eq 0 ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ $failures -eq 0 -a "$console_print" = "true" ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync msg="$msg /var/svc/log/system-manifest-import:default.log ."
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# 3. Profile application. We must create the platform profile upon
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# first boot, as we may be a diskless client of a platform or
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# architecture distinct from our NFS server.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# Generic and platform profiles are only supported in /etc.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # If smf/manifest doesn't have any profile under /etc/var/profile,
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # this is very likely an import after upgrade so call
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync [ $plm != $pl ] && plmn="etc_svc_profile_platform_${plm}_xml"
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync for prof in $pln $plmn etc_svc_profile_platform_none_xml \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if /usr/bin/svcprop -p $prof smf/manifest >/dev/null 2>&1
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ $preserve_profiles -eq 1 ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync echo "/etc/svc system profiles not found: upgrade system profiles"
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ ! -f $prefix/platform.xml ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync elif [ -f $prefix/platform_$this_karch.xml ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# 4. Upgrade handling. The upgrade file generally consists of a series
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# of svcadm(1M) and svccfg(1M) commands.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /var/svc/profile/upgrade.app.`date +\%Y\%m\%d\%H\%M\%S`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Rename the datalink upgrade script file. This script is used in the
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # network/physical service to upgrade datalink configuration, but
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # the file cannot be renamed until now (when the file system becomes
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync "${datalink_script}".app.`date +\%Y\%m\%d\%H\%M\%S`
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# 5. Giving administrator the final say, apply site.xml profile and profiles
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync [ -f $prefix/site.xml ] && svccfg_apply $prefix/site.xml
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ -d $PROFILE_DIR_SITE -a "$1" = "/etc/svc/profile" ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# 0b Cleanup deathrow
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ -s $deathrow ];then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # svc.startd has unconfigured the services found in deathrow,
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # clean them now.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Delete services and instances from the deathrow file.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Remove deathrow manifest hash.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# 0c Clean up repository
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync if [ -z "$X" ] && /usr/bin/svcprop smf/manifest 2>/dev/null |
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/bin/grep '^ar_svc_[^/]*/md5sum opaque ' >/dev/null
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync while read pg prop type value; do
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync echo "Converting obsolete repository entries: \c" > /dev/msglog
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync printf "%${fwidth}s/%${fwidth}s" $i $n > /dev/msglog
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync echo "Converted $n obsolete repository entries"
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# If the alternate repository and directory are specified, simply set
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# SVCCFG_REPOSITORY env, run svccfg import on the given directory, and
1b33c96954667ba382fa595baf7b31290bfdd517vboxsyncif [ -n "$ALT_REPOSITORY" -a -n "$ALT_MFST_DIR" ]; then
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync SVCCFG_REPOSITORY=$ALT_REPOSITORY export SVCCFG_REPOSITORY
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# Call import and apply profiles here
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Process both /lib/svc/manifest and /var/svc/manifest
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # during late manifest-import
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # First import the manifests
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Apply profiles
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync # Run the upgrade script
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# 6. Final actions.
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svcadm _smf_backup "manifest_import" || true
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# If the filesystem is NOT read only then move the repo back to perm
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# There is no care wether the switch was made or not, but just want
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# to move it. If it is already perm this does not affect anything
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync# at least on the surface. REALLY want to improve on this...
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svcadm _smf_repository_switch perm || { \
1b33c96954667ba382fa595baf7b31290bfdd517vboxsync /usr/sbin/svccfg cleanup | /usr/bin/tee /dev/msglog