mm.msg revision cee0fb94c0d4227de0a00efc162fb2739844b641
$
$ CDDL HEADER START
$
$ The contents of this file are subject to the terms of the
$ Common Development and Distribution License (the "License").
$ You may not use this file except in compliance with the License.
$
$ You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
$ or http://www.opensolaris.org/os/licensing.
$ See the License for the specific language governing permissions
$ and limitations under the License.
$
$ When distributing Covered Code, include this CDDL HEADER in each
$ file and include the License file at usr/src/OPENSOLARIS.LICENSE.
$ If applicable, add the following below this CDDL HEADER, with the
$ fields enclosed by brackets "[]" replaced with your own identifying
$ information: Portions Copyright [yyyy] [name of copyright owner]
$
$ CDDL HEADER END
$
$
$ Copyright 2008 Sun Microsystems, Inc. All rights reserved.
$ Use is subject to license terms.
$
$ Media Manager (MM) Message Catalog
$quote "
$ Use same message set number for all mm components.
$set 1
$ MM Operator Messages 1000-1100
$ 1000 operator attended reply message, don't reuse
$ 1001 operator unattended reply message, don't reuse
$ MMS API Messages 3000-3999
3000 "MMS API session pointer is set to NULL."
3001 "MMS API has encountered a previous internal processing error, unable to process API commands."
3002 " "
3003 " "
3004 "MMS API has encountered a memory malloc failure for a new $name$, errno - $errno$."
3005 "MMS API encountered a socket write failure trying to send command with task id $taskid$ to MMS."
3006 "MMS API recevied an invalid response from MMS for command with task id $taskid$."
3007 " "
3008 "MMS API has encountered a taskid mismatch on an accept-unaccept response, expected - $expected$, received - $received$."
3009 " "
3010 "MMS API session socket to MMS is not open."
3011 "MMS API encountered a select failure on socket to MMS with errno - $errno$"
3012 "MMS API detected that MMS has disconnect from client."
3013 "MMS API encountered a response read failure."
3014 "MMS API encountered a missing $part$ in input from MMS."
3015 "MMS API could not find and entry in $list$ with taskid $taskid$."
3016 "MMS API async reader thread could not obtain reading lock"
3017 "MMS API encountered a parse error on input from MMS"
3018 "MMS API has been told to shutdown."
3019 "MMS API session is configured in a mode that does not support this API command."
3050 "MMS API could not read clients network configuration file $file$"
3051 "MMS API failed to connect to MMS due to $error$ error."
3052 "MMS API goodbye command failed to be sent to MMS."
3100 "MMS session is not configured to handle events in a asyncrhonous manner."
3101 "Event with $event$ tag is already registered MMS."
3102 "MMS API received an unacceptable response for a $type$ notify command with $tag$ tag."
3103 "MMS API received a event, but was unable to cleanly obtain the tag clause."
3104 "MMS API was unable to process notify command to obtain tag and object clauses. See API trace for exact error."
3105 "MMS API received a $error$ error trying to register for event with $tag$ tag."
3106 "MMS API received a $error$ error trying to unregister for event with $tag$ tag."
$ MM Messages 5000-5999
5000 "line $line$, col $col$, near token '$token$', err code $code$, $msg$"
5001 "$msg$"
5004 "No such CARTRIDGE.CartridgeID $cartid$."
5005 "No such CARTRIDGE.CartridgePCL $cartpcl$."
5006 "CARTRIDGE.CartridgeID $cartid$ is a mount candidate."
5007 "Only one library is allowed for the eject command. CARTRIDGE.CartridgeID $cartid1$ is in LIBRARY $lib1$ and one or more cartridges are in LIBRARY $lib2$."
5008 "LIBRARY $lib$ doesn't have a configured LM."
5009 "LIBRARY $lib$ has more than one LM configured."
5010 "SLOT not found for CARTRIDGE.CartridgeID $cartid$."
5011 "CARTRIDGE.CartridgeID $cartid$ not in SLOT."
5012 "Internal mm request: $what$"
5013 "Ready for client connections."
5014 "Request by $client$ $inst$ '$text$'"
5015 "Response for $client$ $inst$ '$text$'"
5016 "Request by $client$ $inst$ cancelled"
5017 "Disconnected $client$ $inst$ removed $number$ requests"
5018 "Error Mounting $cartridge$ in $drive$, LM error message: $msg_rsp$"
5019 "No error message associated with this class/token"
5020 "Candidate cartridge, $cartridge$, is in use"
5021 "unrecoverable system error, $text$"
5022 "Drive, $drive$ is temporarily disabled"
5023 "Drive, $drive$ is permenantly disabled"
5024 "Drive, $drive$ is broken"
5025 "Drive, $drive$ is not ready, try again later"
5026 "Drive, $drive$ is not accessible from the library"
5027 "Application, $app$ is not the exclusive app for drive, $drive$"
5028 "Drive, $drive$ is loaded with non-MMS tape"
5029 "Drive, $drive$ is offline"
5030 "Application, $app$ does not have access to drive, $drive$"
5031 "drive, $drive$, reported as not ready by DM, $dm$"
5032 "DM, $dm$, for $drive$ is not connected to MM"
5033 "DM, $dm$, for $drive$ is not connected drive"
5034 "DM, $dm$, for $drive$ is currently configuring"
5035 "DM, $dm$, for $drive$ is not configured yet, DM may need to be activated"
5036 "DM, $dm$, for $drive$ does not support the accessmode contained in the accessmode clause"
5037 "Cartridge, $cart$, has not been located in the library, if this cartridge has been injected try cpscan"
5038 "Cartridge, $cart$, is currently being used by another client"
5039 "Application, $app$ does not have access to cartridge, $cart$"
5040 "Application, $app$ does not have any volumes allocated on cartridge, $cart$"
5041 "Library, $lib$, is currently offline"
5042 "Library, $lib$, is temporarily disabled"
5043 "Library, $lib$, is permanently disabled"
5044 "Library, $lib$, is broken"
5045 "LM, $lm$, reports the device state is not ready"
5046 "LM, $lm$, for library, $lib$, is not connected to MM"
5047 "LM, $lm$, for library, $lib$, is not activated"
5048 "LM, $lm$, is not connected to library, $lib$"
5049 "LM, $lm$, for library, $lib$, is currently configuring"
5050 "No DM configured on host, $host$"
5051 "Mount type must be one of: SIDE PARTITION or VOLUME"
5052 "Could not find any candidate cartridges, check match statement and application-cartridge access"
5053 "Error loading $cartridge$ in $drive$, DM error message: $msg_rsp$"
5054 "Error attaching to handle, $cartridge$ in $drive$, DM error message: $msg_rsp$"
5055 "Device manager communication error, LM/DM error message: $msg_rsp$"
5056 "Could not find any mounted candidate cartridges, check match statement and application-cartridge access"
5057 "library command cannot have both an online and offline clause"
5058 "no matching library exists"
5059 "library $lib$ is already online"
5060 "no matching lm exists"
5061 "library $lib$ is already offline"
5062 "could not find clause/keyword in command"
5063 "no matching drive exists"
5064 "drive $drive$ is already online"
5065 "drive $drive$ has a cartridge mounted"
5066 "drive $drive$ is already online"
5067 "Clause is missing a required arguement, $text$"
5068 "no matching cartridge found for eject"
5069 "no matching cartridge exists"
5070 "To many matching cartridge found"
5071 "Couldn't find $pcl$ in library"
5072 "No LM configured for library, $lib$"
5073 "LM, $lm$, is not in a ready state"
5074 "No DM configured"
5075 "No LM configured"
5076 "Match statement matched more than one device manager"
5077 "DM, $dm$, not connected to MM"
5078 "LM, $lm$, not connected to MM"
5079 "couldn't match any current device managers"
5080 "couldn't use match clause to find any configured LM's"
5081 "LM, $lm$, is not ready/online"
5082 "Standard privilege client may not use the 'who' clause"
5083 "syntax error found parsing the range clause"
5084 "error counting new vols in range"
5085 "not enough partitions exist"
5086 "Creation of PARTITION requires an existing CartridgePCL"
5087 "Creation of PARTITION requires an existing LibraryName"
5088 "Client, $client$, does not have Cartridge group access to $pcl$"
5089 "failed to change request state"
5090 "no matching task found"
5091 "more than one matching task found"
5092 "match returned no results"
5093 "no matching request found"
5094 "no drives found for library $lib$"
5095 "no slot found for cart, $cart$"
5096 "Drive, $drive$, does not support the shape of cart, $cart$"
5097 "drive does not support the cartridge type"
5098 "dm is still reserved, another client may be writing to this tape, $dm$"
5099 "Failed to change $info$."
5100 "Client not connected."
5101 "Client did not receive message."
5102 "drive $drive$ is currently unloading/loading, retry"
5103 "dm $dm$ does not support mount point"
5104 "Requested resources are temporarily unavailable"
5105 "No valid cartridge/library/drive found"
5106 "Old password does not match existing password."
5107 "Unable to update hello command password file $file$."
5108 "Standard privilege client may not modify $object$ $attribute$"
5109 "Administrator privilege client may not modify $object$ $attribute$"
$ DM Messages 6000-6999
6500 "$dm$: syntax error: $error$"
6501 "$dm$: activate $type$ failed: $error$"
6502 "$dm$: reserved. Preempt reservation? reply yes/no/retry."
6503 "$dm$: volume has no label. Enter volume id (VSN) or abort"
6504 "$dm$: USCSICMD error: $error$"
6505 "$dm$: no matching command: $error$"
6506 "$dm$: internal error: $error$"
6507 "$dm$: unknown capability: $error$"
6508 "$dm$: attach error: $error$"
6509 "$dm$: I/O error: $error$"
6510 "$dm$: identify error: $error$"
6511 "$dm$: detach error: $error$"
6512 "$dm$: get request: $error$"
6513 "$dm$: set blocksize error: $error$"
6514 "$dm$: get blocksize error: $error$"
6515 "$dm$: unsupported MTIOCTOP function: $error$"
6516 "$dm$: open error: $error$"
6517 "$dm$: load command error: $error$"
6518 "$dm$: overwrite data on $pcl$? reply yes/no."
6519 "$dm$: switch label from $from$ to $to$ on $pcl$? reply yes/no."
6520 "$dm$: switch label from $from$ to $to$ and writeover data on $pcl$? reply yes/no."
6521 "$dm$: $drive$ is still opened by pid $pid$"
6522 "$dm$: MTSEEK error: $error$"
6523 "$dm$: MTTELL error: $error$"
6524 "$dm$: DM restarting because of attach error: $error$"
6525 "$dm$: DM initialization error: $error$"
6526 "$dm$: DM restarting: $error$"
6527 "$dm$: mount command error: $error$"
6528 "$dm$: DM exiting: $error$"
6529 "$dm$: make handle directory error: $error$"
$ LM Messages 7000-7999
7000 "LM was unable to obtain task id from $cmd$ command."
7001 "Current state of LM does not allow processing a $cmd$ command."
7002 "LM received an invalid command - $cmd$."
7003 "LM received a $cmd$ command after being told to shutdown, command aborted."
7004 "Internal processing error occurred while processing LMPM $cmd$ command."
7005 "Last LMPM $cmd$ command sent to LM contained a syntax error."
7006 "LM received a signal to shutdown, exit code - $ecode$."
7007 "LM is shutting down due to an internal processing error."
7008 ""
7009 "LMPM $cmd$ command has invalid or missing arguments in area of $part$."
7010 "LMPM private command contains a unsupport $type$-name of $name$."
7011 "LMPM private command's set-name $name$ has a illegal set-value of $value$."
7012 "This libraries internal configuration is not a supported configuration for a library of type $type$."
7013 "LM state is changing to $state$."
7014 "LM is active."
7015 "LM is deactivated."
7016 "LM is exiting."
7017 "LM is resetting."
7018 "The library object $object$ or its value is missing."
7019 "The library object $object$ is invalidly configured to $value$."
7020 "Loading a $type$ library module of connection type $conn$ failed."
7021 "LM is shutting down due mmswcr going away."
7022 "LM completed partial reset."
7023 "LM encountered a lmpm_parser syntax error on last LMPL response from MM."
7024 "LM encountered a lmpm_parser syntax error on last input from MM, unable to determine if LMPM command or LMPL response."
7025 "LM encountered a lmpm_parser no memory error."
7026 "LM encountered a unrecoverable lmpm_parser error."
7026 "LMPM $cmd$ command is being aborted due to the LM going inactive or being shutdown."
7030 "During processing of LMPM $cmd$ command, LMPL $lmpl$ command receieved a $rsp$ response from MM."
7032 "During processing of LMPM $cmd$ command, LMPL show command was not able to obtain serial number for drive $drive$."
7033 "During activation of library, Library is configured in MMS as type $type$, ACSLS says library is type $a_type$."
7101 "LMPM $cmd$ command completed successfully."
7102 "Cartridge $cart$ is mounted in drive $drive$."
7103 "Cartridge $cart$ unmounted from drive $drive$."
7104 ""
7105 "LMPM $cmd$ command is a NOP for a $type$ library."
7106 "Cartridge(s) $cart$ injected into library."
7107 "Cartridge(s) $cart$ ejected from library."
7108 "Port $port$ is a valid ACSLS CAP desinator; however, it is not physically configured."
7109 "There were cartridges in CAP, but none were injected into library."
7110 "Cartridge(s) $cart$ were not injected into library."
7111 "Cartridge(s) $cart$ were injected into library; however, unable to locate a slot location."
7112 "CAP was empty, No cartridges injected into library."
7113 "Too many cartridges specified to be ejected into library, max CAP size is $num$."
7114 "Cartridge(s) $cart$ were not ejected from library."
7115 "No cartridges ejected from library."
7116 "LMPM scan command does not support the fromslot and toslot format for $type$ libraries."
7117 "Port $port$ is not a valid ACSLS CAP desinator."
7118 "Scan for cartridges $carts$ found cartridges in slots of library."
7119 "Scan for cartridges $carts$ did not find cartridges in slots of library."
7120 "Scan for cartridges did not find any cartridges in slots of library."
7121 "Scan of drive(s) with geometries $geom$ completed."
7122 "Scan for drive(s) did not find any in library."
7123 "Scan for drive(s) with geometries $geom$ were not found in library."
7124 "Scan of entire library completed."
7125 "Scan of drive(s) $list$ completed."
7126 "No ACSLS geometry found for drive $name$, serial number - $serial$."
7200 "LMPM $cmd$ command failed, ACSLS command $acsls$ returned a status of STATUS_LIBRARY_NOT_AVAILABLE, state of ACSLS server - $state$."
7201 "LMPM $cmd$ command failed, ACSLS command $acsls$ returned a status of STATUS_LIBRARY_NOT_AVAILABLE, state of ACSLS server is non-determinable."
7202 "Received a STATUS_LIBRARY_NOT_AVAILABLE from ACSLS server, state of server - $state$, LM state being switched to broken."
7203 "Communication problem with ACSLS server, status returned from server - $status$, LM state being switched to disconnected."
7204 "Library is currently performing an audit, please retry LMPM $cmd$ command again."
7205 "LMPM $cmd$ command failed, MMS does not have permission to perform ACSLS command $acsls$."
7206 "Received a STATUS_LIBRARY_NOT_AVAILABLE from ACSLS server, state of server is non-determinable, LM state being switched to broken."
7207 "Internal problem with ACSLS server, received a $status$ from server forACSLS command $acsls$, LM state being switched to broken."
7208 "LMPM $cmd$ command failed, ACSLS command $acsls$ returned a status of $status$."
7209 "Library component failure, received a STATUS_LIBRARY_FAILURE from ACSLS server for ACSLS command $acsls$."
7210 "Drive $drive$ is not accessible, drive state is set to offline. Drive's ACSLS geometry is $geom$."
7211 "LSM $lsm$ is set to offline."
7212 "CAP $cap$ is busy, try again."
7213 "CAP $cap$ is set to automatic mode, cannot enter cartridges manually through ACSLS command enter."
7214 "CAP $cap$ is set to offline, ACSLS command $acsls$ cannot access CAP."
7215 "LMPM $cmd$ command failed, drive $drive$ is empty. Cartridge $cart$ is marked as unusable."
7216 "LMPM $cmd$ command failed, ACS $acs$ is full."
7217 "ACS $acs$ is not a valid ACS desinator on ACSLS server."
7218 "LSM $lsm$ is not a valid LSM desinator on ACSLS server."
7219 "Drive $drive$ was not found in ACSLS library. Drive's ACSLS geometry is $geom$."
7220 "Cartridge $cart$ was not found in drive, drive $drive$ is empty. Drive's ACSLS geometry is $geom$."
7221 "Internal communication problem on ACSLS server, ACSLS command $acsls$ received a $status$ from server."
7222 "MMS does not have permission to perform ACSLS command $acsls$, received a STATUS_COMMAND_ACCESS_DENIED from ACSLS server."
7223 "Cartridge $wcart$ was actually unmounted from drive $drive$, MMS expected cartridge $ecart$ to be in the drive."
7224 ""
7225 "LMPM $cmd$ command failed, Communication error with ACSLS server, return status - $status$."
7226 "LMPM $cmd$ command failed, Communication error response from ACSLS command $acsls$, return status - $status$."
7227 "LMPM $cmd$ command failed, Internal acsls processing error, return status - $status$."
7228 "LMPM $cmd$ command failed, Internal ACSLS processing error response for ACSLS command $acsls$, return status - $status$."
7229 "LMPM $cmd$ command failed, Invalid ACSLS status returned, status returned - $status$."
7230 "LMPM $cmd$ command failed, Invalid ACSLS response status from ACSLS command $acsls$, return status - $status$."
7231 "LM exceeded threashold of RT_NONE ACSLS response packets, LM taken offline."
7232 "LMPM $cmd$ command failed, ACSLS command $acsls$ received a non success response, return status - $status$."
7233 "LMPM $cmd$ command failed, ACSLS command $acsls$ received an unexpected return type of $type$."
7234 "LMPM $cmd$ command failed, ACSLS command $acsls$ received an unexpected state in acs_response(), state is $state$."
7235 "$drive$ has a missing/incomplete a drive geometry, drive will be temorarily disabled, offline/online this library and drive to clear the error state"
$ Watcher Messages 8000-8999
8000 "Conflicting ssi configuration on $wcr_host$ , Same SSI port configured for different ACSLS libraries: $lmname1$ $ssiport1$ $ssihost1$ , $lmname2$ $ssiport2$ $ssihost2$"