7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# CDDL HEADER START
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# The contents of this file are subject to the terms of the
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# Common Development and Distribution License (the "License").
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# You may not use this file except in compliance with the License.
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# or http://www.opensolaris.org/os/licensing.
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# See the License for the specific language governing permissions
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# and limitations under the License.
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# When distributing Covered Code, include this CDDL HEADER in each
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# If applicable, add the following below this CDDL HEADER, with the
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# fields enclosed by brackets "[]" replaced with your own identifying
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# information: Portions Copyright [yyyy] [name of copyright owner]
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# CDDL HEADER END
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# DO NOT EDIT -- this file is generated by the Event Registry.
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-1Q
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# keys: fault.config.fan-fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-1Q.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-1Q.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Critical"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-1Q.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The minimum number of required chassis fans '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-1Q.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-1Q.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-1Q.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Check that the minimum required number of fans are configured."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-24
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.config.fantray-fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-24.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-24.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Critical"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-24.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The minimum number of required chassis fan trays '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-24.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-24.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-24.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Check that the minimum required number of fan trays are configured."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-3R
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.config.psu-fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-3R.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-3R.severity"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Critical"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-3R.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The minimum number of required chassis power supplies '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-3R.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-3R.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-3R.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Check that the minimum required number of power supplies are configured."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-42
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.device.controller.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-42.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-42.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-42.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Controller card '%<fault-list[0].location>' is not functioning correctly."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-42.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-42.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric may be in a degraded state."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-42.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-5X
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.device.ethernet.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-5X.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-5X.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-5X.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "An out-of-band management interface failure has occurred on '%<fault-list[0].location>'."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-5X.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-5X.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric may be in a degraded state. User data storage is still available."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-5X.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-6E
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.device.fan.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-6E.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-6E.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-6E.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A fan on '%<fault-list[0].location>' is not functioning correctly."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-6E.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-6E.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The chassis may be getting inadequate cooling. If the problem persists, components may overheat and the chassis may shutdown."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-6E.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-7J
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.device.psu.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-7J.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-7J.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-7J.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Power supply '%<fault-list[0].location>' is not functioning correctly."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-7J.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-7J.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-7J.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-8S
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.device.sas-expander.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-8S.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-8S.severity"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-8S.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A SAS expander on '%<fault-list[0].location>' is not functioning correctly."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-8S.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-8S.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric is in a degraded state. User data storage may be degraded or unavailable."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-8S.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-95
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.device.unusable-chassis-id
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-95.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-95.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Critical"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-95.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The chassis ID was determined to be unusable."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-95.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-95.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric is down, and user data storage is unavailable."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-95.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-AP
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.io.i2c.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-AP.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-AP.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Critical"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-AP.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "An I2C bus on '%<fault-list[0].location>' is not functioning correctly."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-AP.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-AP.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The system is in an unknown state."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-AP.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-CA
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.io.sas.log.fatal
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-CA.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-CA.severity"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Critical"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-CA.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A fatal error has been detected by a SAS expander on '%<fault-list[0].location>' requiring it to reset."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-CA.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-CA.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS expander is not functioning correctly. The SAS fabric will be in a degraded state while the expander resets. Downstream devices may be inaccessible."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-CA.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-DH
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.io.sas.log.non-fatal
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-DH.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-DH.severity"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-DH.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A non-fatal error has been detected by a SAS expander on '%<fault-list[0].location>'."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-DH.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-DH.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS expander may not be functioning correctly. The SAS fabric may be in a degraded state. Downstream devices may be inaccessible."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-DH.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-ED
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.power.ext-fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-ED.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-ED.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-ED.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A power failure external to the chassis has occurred."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-ED.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "None."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-ED.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-ED.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Check that external AC power is available and that all the power cords are plugged into the chassis power supplies."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-FY
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydan# keys: fault.power.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-FY.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-FY.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-FY.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A power failure has occurred on '%<fault-list[0].location>'."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-FY.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-FY.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A device in the chassis may be getting inadequate power. Subsequent loss of the device may force the chassis to shutdown."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-FY.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-G3
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# keys: fault.sensor.read-fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-G3.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-G3.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-G3.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "An attempt to read a sensor on '%<fault-list[0].location>' failed."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-G3.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-G3.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Data from the affected sensor will be unavailable. Data from other sensors may be used instead if available."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-G3.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-HR
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# keys: fault.sp.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-HR.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-HR.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Critical"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-HR.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A Service Processor on '%<fault-list[0].location>' is not functioning correctly."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-HR.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-HR.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric may be in a degraded state."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-HR.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-J4
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# keys: fault.sp.unavailable
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-J4.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-J4.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-J4.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A Service Processor has detected that its peer is unavailable."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-J4.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-J4.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "IMP_FAB_MB_DEG"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-J4.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-KQ
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# keys: fault.sp.svc-fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-KQ.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-KQ.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-KQ.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A Service Processor software service failure has occurred on '%<fault-list[0].location>'. The service which restarted was '%<fault-list[0].resource.hc-specific.service>'."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-KQ.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-KQ.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The SAS fabric may be in a degraded state. User data storage is still available."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-KQ.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# code: STORAGE-8000-LC
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan# keys: fault.temp.fail
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydan#
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-LC.type"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Fault"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-LC.severity"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgstr "Major"
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-LC.description"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Ambient temperature is outside of normal operating range."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-LC.response"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "The service required LED on the chassis will be illuminated."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-LC.impact"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "A device in the chassis may be overheating. Subsequent loss of the device may force the chassis to shutdown."
7851b394eaf422b4e39062c8bdecfbd8b9c79dd0Tarik Soydanmsgid "STORAGE-8000-LC.action"
c27f025d34302f23b772782922d25dfcd4c33250Tarik Soydanmsgstr "Check that the ambient temperature is adequately cool, and none of the chassis air inlets are blocked."