724365f7556fc4201fdb11766ebc6bd918523130sethg#
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China# Copyright 2008 Sun Microsystems, Inc. All rights reserved.
724365f7556fc4201fdb11766ebc6bd918523130sethg# Use is subject to license terms.
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# CDDL HEADER START
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# The contents of this file are subject to the terms of the
724365f7556fc4201fdb11766ebc6bd918523130sethg# Common Development and Distribution License (the "License").
724365f7556fc4201fdb11766ebc6bd918523130sethg# You may not use this file except in compliance with the License.
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
724365f7556fc4201fdb11766ebc6bd918523130sethg# or http://www.opensolaris.org/os/licensing.
724365f7556fc4201fdb11766ebc6bd918523130sethg# See the License for the specific language governing permissions
724365f7556fc4201fdb11766ebc6bd918523130sethg# and limitations under the License.
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# When distributing Covered Code, include this CDDL HEADER in each
724365f7556fc4201fdb11766ebc6bd918523130sethg# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
724365f7556fc4201fdb11766ebc6bd918523130sethg# If applicable, add the following below this CDDL HEADER, with the
724365f7556fc4201fdb11766ebc6bd918523130sethg# fields enclosed by brackets "[]" replaced with your own identifying
724365f7556fc4201fdb11766ebc6bd918523130sethg# information: Portions Copyright [yyyy] [name of copyright owner]
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# CDDL HEADER END
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# DO NOT EDIT -- this file is generated by the Event Registry.
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# code: DISK-8000-0X
724365f7556fc4201fdb11766ebc6bd918523130sethg# keys: fault.io.disk.predictive-failure
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-0X.type"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Fault"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-0X.severity"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Major"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-0X.description"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information."
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-0X.response"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "None.\n"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-0X.impact"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-0X.action"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# code: DISK-8000-12
724365f7556fc4201fdb11766ebc6bd918523130sethg# keys: fault.io.disk.over-temperature
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-12.type"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Fault"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-12.severity"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Major"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-12.description"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information."
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-12.response"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "None.\n"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-12.impact"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-12.action"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethg# code: DISK-8000-2J
724365f7556fc4201fdb11766ebc6bd918523130sethg# keys: fault.io.disk.self-test-failure
724365f7556fc4201fdb11766ebc6bd918523130sethg#
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-2J.type"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Fault"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-2J.severity"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Critical"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-2J.description"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "One or more disk self tests failed.\n Refer to %s for more information."
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-2J.response"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "None.\n"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-2J.impact"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "The disk has failed.\n"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgid "DISK-8000-2J.action"
724365f7556fc4201fdb11766ebc6bd918523130sethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China#
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China# code: DISK-8000-3E
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.derr
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China#
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.type"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.severity"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.description"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information."
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.response"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.impact"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "The device has failed. The service may have been lost or degraded.\n"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.action"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China#
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China# code: DISK-8000-4Q
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.merr
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing China#
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.type"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.severity"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.description"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information."
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.response"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.impact"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.action"
9e1c849eae563842996c64c805047e840c75fc79David Zhang - Sun Microsystems - Beijing Chinamsgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"